EPA requirements according to DIN EN 61340-5-1

 
ESD control element Produktqualifizierunga Verifizierung der Einhaltungb
Prüfverfahren Grenzwertec Basierend auf Prüfverfahren Grenzwertec

Work surfaces, storage shelves and transport trolleysg
 
IEC 61340-2-3 Rgp < 1 x 109 Ω 
Rp-p < 1 x 109
IEC 61340-2-3 Rg < 1 x 109
Wrist strap connection point
- - - Rg < 5 x 106
Flooring
IEC 61340-4-1d, e
 
Rgp < 1 x 109 Ω  IEC 61340-4-1 Rg < 5 x 109
Ionization IEC 61340-4-7
Decay (1000 V to 100 V and 
-1000 V to -100 V) < 20 s
Offset voltage < +/- 35 V
 
IEC 61340-4-7 Decay (1000 V to 100 V and 
-1000 V to -100 V) < 20 s or user-defined
offset voltage < +/- 35 V
Seating
IEC 61340-2-3 (measurement of resistance to groundable point)
 
Rgp < 1 x 109 Ω  IEC 61340-2-3 (measurement of resistance
to ground)
Rg < 1 x 109
EPA-clothing
IEC 61340-4-9 or user-defined procedure
 
Rp-p < 1 x 1011 Ω or user-defined threshold IEC 61340-4-9 or user-defined procedure Rp-p < 1 x 1011 Ω or user-defined threshold
Groundable EPA clothing
IEC 61340-4-9
 
Rgp < 1 x 109 Ω  IEC 61340-4-9 Rgp < 1 x 109 Ω 
 
 
a For product qualification, the environmental conditions for the test should be (12 ± 3) % relative humidity and (23 ± 2) °C. Unless specified in the referenced IEC standards, the minimum ambient temperature conditioning time for product qualification should be 48 h.
b The test methods in the compliance verification column refer only to the basic test method. The test methods are not expected to be fully followed
c Symbols used in this table: Rp-p refers to point-to-point resistance, Rg corresponds to resistance to ground and Rgp refers to resistance to groundable point.
d he maximum admissible test voltage for the measurement of ESD floor coverings to be used for an ESD program that complies with this standard is 100 V.
e If a flooring is used to ground the personnel handling ESDS, reference is made to the system requirements in table 2.
f In situations where damage from the Charged Device Model (CDM) must be considered, a lower threshold of the point-to-point resistance Rp-p of 1 x 104 Ω is recommended.
g Working surfaces are defined as any surface on which an ESD-sensitive element is placed.

 